Skip to main content Skip to main navigation menu Skip to site footer

Kajian Unjuk Kerja Pemanas Air Tenaga Matahari Sistim Pipa Panas Menggunakan R-134a

A Study of Solar Power Water Heater Performance on Hot Pipe System by Using R-134a

Authors
  • Jesayas Sembiring Universitas Sumatera Utara
  • Himsar Ambarita Universitas Sumatera Utara
  • Farel H. Napitupulu Universitas Sumatera Utara
Issue       Vol 1 No 1 (2018): Talenta Conference Series: Energy and Engineering (EE)
Section       Articles
Galley      
DOI: https://doi.org/10.32734/ee.v1i1.105
Keywords: tenaga matahari refrigerant kaca penutup pipa panas efisiensi kolektor
Published 2018-10-16

Abstract

Suhu bumi saat ini semakin meningkat dan sumber energi fosil semakin menipis, ini perlu disikapi secara bijak untuk menjaga keamanan dan kenyamanan kehidupan manusia dimasa depan, melalui usaha pemanfaatan energi baru dan terbarukan. Energi terbarukan adalah sumber energi yang dihasilkan dari potensi sumber daya alam, yang secara ilmiah tidak dapat habis dan dapat berkelanjutan bila dikelola dengan baik, antara lain: air terjun, tenaga angin dan tenaga matahari. Indonesia memiliki potensi tenaga matahari yang tidak terbatas karena terletak pada daerah lintasan matahari. Penelitian ini dilakukan untuk mengetahui besar efisiensi kolektor matahari menggunakan fluida kerja R134a dengan variasi tekanan dan penutup kolektor. Pemanas air tenaga matahari menggunakan fluida kerja R134a merupakan alat memproduksi air panas untuk memenuhi kebutuhan air panas dan diharapkan menjadi salah satu solusinya. Penelitian dua tahap: tahap pertama dua kaca penutup dan tahap kedua satu kaca penutup dengan variasi tekanan. Penelitian ini menawarkan tiga hal sebagai kesimpulan. Pertama, Dari hasil penelitian diketahui temperatur air meningkat seiring dengan meningkatnya tekanan fluida kerja. Kedua, Dari hasil kajian secara menyeluruh efisiensi kolektor meningkat seiring dengan meningkatnya temperatur air. Ketiga, Menggunakan dua kaca penutup kolektor lebih baik dari pada menggunakan sebuah kaca penutup kolektor. Menggunakan dua kaca penutup kolektor menghasilkan efisiensi terbaik: 35,49% dan satu kaca penutup kolektor efisiensi terbaik: 17,77% pada tekanan 110 psi. Secara umum dapat dikatakan bahwa: kajian unjuk kerja pemanas air tenaga matahari sistim pipa panas menggunakan fluida kerja R134a hasilnya baik, lebih efisien menggunakan dua buah kaca penutup dibandingkan hanya menggunakan satu kaca penutup kolektor.

 

The temperature of earth is currently increasing and fossil energy sources are depleting. This condition needs to be managed wisely to maintain the security and comfort of human life in the future, i.e. by using new and renewable energy. Renewable energy is a source of energy produced from potential natural resources, which scientifically could not be exhausted and could be sustainable if it is managed properly, such as waterfalls, wind power and solar energy. Indonesia has unlimited potential solar power because it is located in the track of the sun. This study was conducted to determine the efficiency of solar collector using the working fluid of R134a with the variations of collector pressure and cover. Solar powered water heater which is using working fluids R134a is a tool for producing hot water to meet hot water needs and expected to be such a solution. This was two-stage study, the first stage was using two cover glass and the second stage was using one cover glass with various pressures. This research offered three things as a conclusion. Firstly, it was showed that water temperature increased along with the increasing of working fluid pressure. The second result of comprehensive study was that the efficiency of the collector increased along with the increasing of water temperature. And the third result was showed by using two collector cover glass was better than using one collector cover glass. Using two collector cover glass produced the best efficiency of 35.49% and one collector cover glass produced the best efficiency of 17.77% at a pressure of 110 psi. In general, it can be said that the study of the performance of solar power water heater on hot pipe system by using the R134a working fluid is good, and more efficient if it uses two glass covers than using only one collector glass cover.